KGNTP
Flame-retardant flexible power cable
KGNTP is a low-fire-hazard modification of KGTP: it does not propagate flame in bunched installation. It is used for mobile equipment in places with an increased fire risk. Designation breakdown: K – cable, G – flexible, N – flame-retardant (does not propagate flame), TP – thermoplastic elastomers.
KGNTP PRODUCT RANGE
Standard sizes from the TCG product range. Manufacture to special order is possible.
| Type / size | Cores | Cross-section, mm² | Voltage | Application |
|---|---|---|---|---|
| KGNTP 1×1 | 1 | 1 | 660 V | Control circuits |
| KGNTP 1×2.5 | 1 | 2.5 | 660 V | Single-phase supply |
| KGNTP 1×4 | 1 | 4 | 660 V | Single-phase supply |
| KGNTP 1×6 | 1 | 6 | 660 V | Single-phase supply |
| KGNTP 1×10 | 1 | 10 | 660 V | Single-phase supply |
| KGNTP 1×16 | 1 | 16 | 660 V | Single-phase supply |
| KGNTP 1×25 | 1 | 25 | 660 V | Single-phase supply |
| KGNTP 1×35 | 1 | 35 | 660 V | Single-phase supply |
| KGNTP 1×50 | 1 | 50 | 660 V | Single-phase / welding |
| KGNTP 1×70 | 1 | 70 | 660 V | Welding |
| KGNTP 1×95 | 1 | 95 | 660 V | Trunk supply |
| KGNTP 3×2.5 | 3 | 2.5 | 660 V | Three-phase supply |
| KGNTP 3×4 | 3 | 4 | 660 V | Three-phase supply |
| KGNTP 3×6 | 3 | 6 | 660 V | Three-phase supply |
| KGNTP 3×10 | 3 | 10 | 660 V | Three-phase supply |
| KGNTP 3×16 | 3 | 16 | 660 V | Three-phase supply |
| KGNTP 3×25 | 3 | 25 | 660 V | Three-phase equipment |
| KGNTP 3×35 | 3 | 35 | 660 V | Three-phase equipment |
| KGNTP 3×50 | 3 | 50 | 660 V | Mobile substations |
| KGNTP 3×70 | 3 | 70 | 660 V | Mobile substations |
Description of KGNTP cable
KGNTP is a low-fire-hazard flexible cable for connecting mobile equipment in places with an increased fire risk. All flexibility and durability characteristics are identical to KGTP, while the insulation and sheath do not propagate flame in bunched installation.
It is used at production sites with combustible materials, in switchgear with bunched cable installation and for connecting machines in workshops with a fire risk. The additional letter N in the designation indicates the flame-retardant property.
Applications
Construction
Conductors
Stranded copper, flexibility class 5.
Insulation
Low-fire-hazard styrenic thermoplastic elastomers.
Stranding
The insulated cores are stranded together into a cable core.
Sheath
Styrenic thermoplastic elastomers, flame-retardant in bunched installation.
Cross-section of KGNTP – flexible copper conductors + low-flammability TPE (orange tint)
Technical specifications
Detailed specifications (load current, resistance, weight) are given in the TCG datasheet
Operating conditions
DOCUMENTS
REQUEST A PRICE
Specify the cross-section and quantity and we will prepare a proposal within 1 business day.