Cable finder
+998 (97) 748-80-00 +998 (71) 287-42-42 info@tcg.uz
KVVGE Screened
Control cables + armoured GOST 1508-78

KVVGE

Screened control cable with copper conductors

KVVGE is a control cable with a copper screen over the stranded insulated cores. The screen protects control circuit signals from external electromagnetic interference (electric motors, variable-frequency drives, power busbars). It is used in industrial process control systems and systems with sensitive electronics. Designation breakdown of the added letter: E – screen.

Voltage 660 V AC / 1000 V DC
Feature Copper screen
Cores 4 – 37
Cross-section 0.75 – 10 mm²

KVVGE PRODUCT RANGE

Sizes with actual technical specifications from TCG factory data.

TypeCoresCross-section, mm²IEC equivalentOuter Ø, mmWeight, kg/km
KVVGE 5×1.551.5NYCY14.8251
KVVGE 5×2.552.5NYCY16.1316
KVVGE 7×1.571.5NYCY16.7309
KVVGE 7×2.572.5NYCY18.5403
KVVGE 8×1.581.5NYCY17.4344
KVVGE 8×2.582.5NYCY19442
KVVGE 10×1.5101.5NYCY18.4399
KVVGE 10×2.5102.5NYCY20.4527
KVVGE 12×1.5121.5NYCY19.3453
KVVGE 12×2.5122.5NYCY21.4602
KVVGE 14×1.5141.5NYCY20.4514
KVVGE 14×2.5142.5NYCY22.4676
KVVGE 16×1.5161.5NYCY21.2566
KVVGE 16×2.5162.5NYCY23.5760
KVVGE 18×1.5181.5NYCY21.9618
KVVGE 18×2.5182.5NYCY24.3832
KVVGE 20×1.5201.5NYCY22.8679
KVVGE 20×2.5202.5NYCY25.3916
KVVGE 24×1.5241.5NYCY24.1780
KVVGE 24×2.5242.5NYCY26.81059
KVVGE 30×1.5301.5NYCY26941
KVVGE 30×2.5302.5NYCY28.91284
The table lists 5-30-core versions with 1.5 and 2.5 mm² cross-sections – the most common in industrial process control systems. The full range under GOST 1508-78: 4-37 cores, cross-sections 0.75; 1; 1.5; 2.5; 4; 6; 10 mm². The exact product range is available on request.

KVVGE cable description

KVVGE is the screened version of KVVG for installation in places with strong electromagnetic interference. The copper screen over the stranded cores reduces the effect of external interference from motors, variable-frequency drives and power busbars – critical for 4-20 mA analogue signals, measuring circuits and sensor communication lines.

It is used in industrial process control systems at industrial plants, in automation systems at power facilities, and for connecting sensitive electronics to controllers. The screen must be earthed (usually at one end – on the PLC side) for effective protection against interference.

Applications

Industrial process control circuits connected to PLCs and controllers
Signal lines carrying 4-20 mA analogue signals
Places with strong electromagnetic interference (near power busbars and variable-frequency drives)
Measuring and communication circuits for temperature and pressure sensors
Protection of sensitive circuits from interference induced by industrial equipment

Construction

1

Conductors

Solid copper with colour coding.

2

Insulation

PVC compound.

3

Stranding

The insulated cores are stranded together to form the cable core.

4

Electromagnetic screen

Tinned copper wires forming a dense braid over the stranded cores. Coverage of at least 80%. Protects signals from external electromagnetic interference.

5

Sheath

Black PVC compound.

KVVGE cross-section – copper conductors + copper screening braid around the stranded cores

Technical specifications

Rated voltage AC 660 V, up to 100 Hz
Rated voltage DC up to 1000 V
Conductor material Copper
Insulation PVC compound
Screen Tinned copper wires, ≥ 80% coverage
Sheath PVC compound
Number of cores 4, 5, 7, 10, 14, 19, 27, 37
Cross-sections 0.75 – 10 mm²
IEC equivalent NYCY
Standard GOST 1508-78

Detailed specifications (conductor resistance, load current) – see the TCG datasheet

Operating conditions

Installation temperature not below -15°C
Operating temperature -50°C … +50°C
Max. conductor t° (continuous) +70°C
Max. conductor t° (short circuit) +160°C
Air humidity up to 98% at +35°C
Min. bending radius 7.5 × Ø (single-core), 10 × Ø (multi-core)
Service life at least 30 years
Warranty 5 years
Climatic category UHL

DOCUMENTS

REQUEST A PRICE

Specify the cross-section and quantity and we will prepare a proposal within 1 business day.