Power cable with Al conductors, XLPE and low-flammability PVC
APvVGng(A)-LS is an aluminium power cable with XLPE insulation and a low-fire-hazard PVC sheath (ng — does not propagate flame, category A) with low smoke and gas emission (LS — Low Smoke). The most economical solution for distribution networks in places with large numbers of people.
The geometry is identical to APvVG; the difference is in the composition of the outer-sheath PVC compound. Full range of cross-sections: 2.5 — 1000 mm².
| Type / size | Cores | Cross-section, mm² | IEC equivalent | Outer Ø, mm | Weight, kg/km | Current (in air), A |
|---|---|---|---|---|---|---|
| APvVGng(A)-LS 3×16 | 3 | 16 | — | 17.8 | 321 | 77 |
| APvVGng(A)-LS 3×25 | 3 | 25 | — | 21.3 | 457 | 97 |
| APvVGng(A)-LS 3×35 | 3 | 35 | — | 23.7 | 579 | 120 |
| APvVGng(A)-LS 3×50 | 3 | 50 | — | 24.9 | 746 | 146 |
| APvVGng(A)-LS 3×70 | 3 | 70 | — | 28.4 | 987 | 187 |
| APvVGng(A)-LS 3×95 | 3 | 95 | — | 32 | 1286 | 227 |
| APvVGng(A)-LS 3×120 | 3 | 120 | — | 35.3 | 1569 | 263 |
| APvVGng(A)-LS 3×150 | 3 | 150 | — | 39.2 | 1925 | 304 |
| APvVGng(A)-LS 3×185 | 3 | 185 | — | 43.6 | 2377 | 347 |
| APvVGng(A)-LS 3×240 | 3 | 240 | — | 48.4 | 2972 | 409 |
| APvVGng(A)-LS 3×300 | 3 | 300 | — | 53.6 | 3495 | 471 |
| APvVGng(A)-LS 4×16 | 4 | 16 | — | 19.5 | 394 | 77 |
| APvVGng(A)-LS 4×25 | 4 | 25 | — | 23.4 | 567 | 97 |
| APvVGng(A)-LS 4×35 | 4 | 35 | — | 26.1 | 724 | 120 |
| APvVGng(A)-LS 4×50 | 4 | 50 | — | 27.5 | 944 | 146 |
| APvVGng(A)-LS 4×70 | 4 | 70 | — | 31.8 | 1286 | 187 |
| APvVGng(A)-LS 4×95 | 4 | 95 | — | 35.4 | 1639 | 227 |
| APvVGng(A)-LS 4×120 | 4 | 120 | — | 39 | 2008 | 263 |
| APvVGng(A)-LS 4×150 | 4 | 150 | — | 43.8 | 2514 | 304 |
| APvVGng(A)-LS 4×185 | 4 | 185 | — | 48.3 | 3054 | 347 |
| APvVGng(A)-LS 4×240 | 4 | 240 | — | 54.2 | 3884 | 409 |
APvVGng(A)-LS is a modification of APvVG for facilities with stricter fire safety requirements, while retaining maximum economy thanks to the aluminium conductors. Cross-linked polyethylene insulation (with a thermal rating of +90°C) is combined with a sheath of low-fire-hazard, low-smoke PVC compound.
Used in the trunk distribution networks of hospitals, schools, shopping malls, metro systems and high-rise buildings — wherever fire safety, high currents and savings on conductor material are all required. For example: supplying the power equipment of a shopping mall from the central substation.
Conductors
Stranded aluminium.
Insulation
Cross-linked polyethylene (XLPE), +90°C continuous.
Stranding
The insulated cores are laid up into a cable core, with tape wrapping where required.
Sheath
Low-fire-hazard PVC compound with low smoke and gas emission (LS).
Cross-section of APvVGng(A)-LS – Al cores in XLPE + low-flammability PVC
Full product range – see the TCG datasheet
Specify the cross-section and quantity and we will prepare a proposal within 1 business day.
Our HR specialist will contact you within two business days
Send us a request and we will prepare a commercial proposal within 1 business day
Describe your task and we will calculate and send a proposal within 1 business day