0.66/1 kV power cable with copper conductors and PVC insulation
VVG — power cable with stranded copper conductors, PVC compound insulation and sheath, without a protective covering. Used for the transmission and distribution of electricity in fixed installations up to 1 kV — in cable structures, indoor premises and on cable racks. Designation breakdown: V — PVC insulation, V — PVC sheath, G — unarmoured.
Sizes with actual technical specifications: outer diameter, weight, continuous current-carrying capacity (in air at +25°C). Full range of cross-sections per GOST 31996-2012: 1.5 — 800 mm².
| Type / size | Cores | Cross-section, mm² | IEC equivalent | Outer Ø, mm | Weight, kg/km | Current (in air), A |
|---|---|---|---|---|---|---|
| VVG 3×1.5 | 3 | 1.5 | NYY | 11 | 147 | 18.5 |
| VVG 3×2.5 | 3 | 2.5 | NYY | 12 | 188 | 25 |
| VVG 3×4 | 3 | 4 | NYY | 14 | 263 | 34 |
| VVG 3×6 | 3 | 6 | NYY | 15.2 | 335 | 43 |
| VVG 3×10 | 3 | 10 | NYY | 17 | 469 | 60 |
| VVG 3×16 | 3 | 16 | NYY | 19.2 | 661 | 80 |
| VVG 3×25 | 3 | 25 | NYY | 22.7 | 972 | 101 |
| VVG 3×35 | 3 | 35 | NYY | 25.1 | 1278 | 126 |
| VVG 3×50 | 3 | 50 | NYY | 26.6 | 1742 | 153 |
| VVG 3×70 | 3 | 70 | NYY | 29.6 | 2332 | 196 |
| VVG 3×95 | 3 | 95 | NYY | 34.1 | 3138 | 238 |
| VVG 3×120 | 3 | 120 | NYY | 36.9 | 3853 | 276 |
| VVG 3×150 | 3 | 150 | NYY | 40.8 | 4768 | 319 |
| VVG 3×185 | 3 | 185 | NYY | 45.3 | 5870 | 364 |
| VVG 3×240 | 3 | 240 | NYY | 50.5 | 7506 | 430 |
| VVG 4×2.5 | 4 | 2.5 | NYY | 12.9 | 229 | 25 |
| VVG 4×4 | 4 | 4 | NYY | 15.2 | 326 | 34 |
| VVG 4×6 | 4 | 6 | NYY | 16.5 | 419 | 43 |
| VVG 4×10 | 4 | 10 | NYY | 18.6 | 593 | 60 |
| VVG 4×16 | 4 | 16 | NYY | 21 | 844 | 80 |
| VVG 4×25 | 4 | 25 | NYY | 25 | 1251 | 101 |
| VVG 4×35 | 4 | 35 | NYY | 27.6 | 1653 | 126 |
| VVG 4×50 | 4 | 50 | NYY | 29.3 | 2268 | 153 |
| VVG 4×70 | 4 | 70 | NYY | 33.2 | 3078 | 196 |
| VVG 4×95 | 4 | 95 | NYY | 37.7 | 4104 | 238 |
| VVG 4×120 | 4 | 120 | NYY | 41.3 | 5088 | 276 |
| VVG 4×150 | 4 | 150 | NYY | 45.7 | 6301 | 319 |
| VVG 5×2.5 | 5 | 2.5 | NYY | 13.5 | 267 | 25 |
| VVG 5×4 | 5 | 4 | NYY | 15.9 | 384 | 34 |
| VVG 5×6 | 5 | 6 | NYY | 17.3 | 497 | 43 |
| VVG 5×10 | 5 | 10 | NYY | 19.6 | 710 | 60 |
| VVG 5×16 | 5 | 16 | NYY | 22.2 | 1019 | 80 |
VVG is the most widely used power cable in Uzbekistan for fixed electrical installations. Stranded copper conductors (1, 2, 3, 4 or 5 cores) are insulated with colour-coded PVC compound. On the outside — a common PVC sheath, without a protective covering. Conductor cross-section: from 1.5 to 800 mm². Rated voltage: 0.66 / 1 kV at a frequency of 50 Hz.
Advantages: long service life (≥30 years), wide temperature range (-50…+50°C), resistance to weathering, easy installation. Not intended for installation in the ground without additional protection — choose VBShv for that.
Conductors
Stranded copper, round or sector-shaped, 1, 2, 3, 4 or 5 cores.
Insulation
Polyvinyl chloride compound, applied to each core with colour coding.
Stranding
The insulated cores are stranded into the cable core.
Sheath
Polyvinyl chloride compound, black. Without a protective covering.
Cross-section of 3-core VVG (copper conductors in PVC insulation)
Full product range – see the TCG datasheet
Specify the cross-section and quantity and we will prepare a proposal within 1 business day.
Our HR specialist will contact you within two business days
Send us a request and we will prepare a commercial proposal within 1 business day