Fire-resistant

POWER CABLES 1 KV • FIRE-RESISTANT

Fire-resistant ng-FRLS LTx power cables with a mica fire barrier

TCG fire-resistant power cables for fire protection systems, emergency lighting, firefighters' lifts and other critical loads. The construction includes a thermal barrier of mica-containing tapes, which keeps the cable operational at a fire temperature of ≥750°C for at least 90 minutes. Insulation and sheath of low-fire-hazard PVC compound (ng, cat. A) with low smoke emission (LS).

Fire resistance FR – keeps operating under fire
Smoke emission LS – low (Low Smoke)
Fire barrier Mica-containing tape
Voltage up to 1 kV
VVGng(A)-FRLS FR + LS

VVGng(A)-FRLS

GOST R 53316
Fire-resistant power cable with copper conductors and a mica fire barrier
Voltage 0.66/1 kV
Conductor Copper
Fire resistance FR + ng(A) + LS
Cross-section 1.5 – 1000 mm²
Product range:
3×1.5 3×2.5 3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150
VBShvng(A)-FRLS FR + LS + armour

VBShvng(A)-FRLS

GOST R 53316
Fire-resistant armoured power cable with a mica fire barrier
Voltage 0.66/1 kV
Conductor Copper
Protection FR + ng(A) + LS + armour
Cross-section 2.5 – 240 mm²
Product range:
3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150
PBPng(A)-FRHF FR + HF + armour

PBPng(A)-FRHF

GOST R 53316
Armoured fire-resistant halogen-free power cable
Voltage up to 3 kV
Conductor Copper
Protection FR + HF + armour
Cross-section 1.5 – 1000 mm²
Product range:
3×2.5 3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×4 4×6 4×10 4×16 4×25 4×35 4×50

COMPARISON OF FIRE-RESISTANT TYPES

ParameterVVGng(A)-FRLSVBShvng(A)-FRLS
ApplicationFire safety systems, emergency lighting, smoke extractionSame + installation in ground and under mechanical loads
ConductorCopper, strandedCopper, stranded
Fire barrierMica-containing tape over the conductorMica-containing tape over the conductor
InsulationLow-fire-hazard PVC compoundLow-fire-hazard PVC compound
Protective coveringsUnarmouredArmour of 2 steel tapes + PVC sheath
Flame propagationDoes not propagate (ng, cat. A)Does not propagate (ng, cat. A)
Fire resistanceFR ≥ 90 minutes (GOST R 53316)FR ≥ 90 minutes
Smoke emission5–7 times lower vs standard PVC (LS)Same
Number of cores1–51–5
Cross-sections, mm²1.5–10002.5–240
Voltage0.66/1 kV (up to 3 kV)0.66/1 kV
StandardGOST 31996-2012, GOST 31565-2012, GOST R 53316GOST 31996-2012, GOST 31565-2012