Power cables 6/10/35 kV GOST R 55025-2012

APVBVNG(A)

Armoured low-fire-hazard power cable 6-35 kV

APvBVng(A) is the armoured version of APvV with a low-fire-hazard PVC sheath (ng, category A). It is used for MV trunk lines installed in ground or under mechanical loads at facilities with stricter fire safety requirements for bunched installation.

Voltage 6 – 35 kV
Conductor Aluminium
Protection Armour + PVC ng
Cross-section 25 – 800 mm²

APvBVng(A) PRODUCT RANGE

Armoured cables with a low-fire-hazard outer sheath.

Type / sizeCoresCross-section, mm²VoltageCopper screen, mm²Outer Ø, mmWeight, kg/km
APvBVng(A) 1×251256/10 kV16——
APvBVng(A) 1×351356/10 kV16——
APvBVng(A) 1×501506/10 kV16——
APvBVng(A) 1×701706/10 kV16——
APvBVng(A) 1×951956/10 kV16——
APvBVng(A) 1×12011206/10 kV16——
APvBVng(A) 1×15011506/10 kV16——
APvBVng(A) 1×18511856/10 kV16——
APvBVng(A) 1×24012406/10 kV25——
Complies with GOST 31565-2012.

APvBVng(A) cable description

APvBVng(A) is an armoured MV cable with a low-fire-hazard outer sheath. It combines three advantages: XLPE insulation (reliability under overload), steel armour (mechanical protection for installation in ground) and low-flammability PVC (does not propagate flame in bunched installation at fire-hazardous facilities).

It is used for MV trunk lines in the underground structures of shopping malls, metro systems and office centres with their own substations – wherever a cable laid in ground must meet fire safety requirements at the point where it enters the premises.

Applications

MV trunk lines in ground beneath high-occupancy facilities
Underground transformer substations of shopping and office centres
Routes between buildings with bunched cable installation
Conditions with mechanical loads + fire safety requirements
Replacement for APvBV in bunched installation

Construction

1

Conductor

Aluminium, stranded.

2

Screens + XLPE

3

Copper wire screen

4

Bedding under armour

5

Armour

2 galvanised steel tapes.

6

Outer sheath

Low-fire-hazard PVC compound (ng, cat. A).

APvBVng(A) cross-section – XLPE + armour + low-fire-hazard PVC sheath

Technical specifications

Rated voltage 6 / 10 / 15 / 20 / 35 kV
Conductor material Aluminium
Insulation Cross-linked polyethylene (XLPE)
Armour 2 galvanised steel tapes
Outer sheath Low-fire-hazard PVC
Flame propagation Does not propagate, category A
Number of cores 1 or 3
Cross-sections 25 – 800 mm²
Standard GOST R 55025-2012 / O'z DSt IEC 60502-2

Detailed specifications – see the TCG datasheet

Operating conditions

Installation temperature not below -20°C
Operating temperature -50°C … +50°C
Max. conductor t° (continuous) +90°C
Max. conductor t° (short circuit) +250°C
Air humidity up to 98% at +35°C
Min. bending radius 15 × Ø (single-core), 25 × Ø (three-core)
Service life at least 30 years
Warranty 5 years
Climatic category UHL