Cable finder
+998 (97) 748-80-00 +998 (71) 287-42-42 info@tcg.uz
SIPst-3 20 kV
SIP wires IEC: SAX

SIPST-3

Single-core self-supporting covered conductor for 6–20 kV overhead lines, reinforced with steel wire

Single-core self-supporting covered conductor with a conductor of aluminium wires reinforced with steel wire (index “st”). The protective insulation of UV-stabilised cross-linked polyethylene allows operation in contact with tree branches and in polluted atmospheres. For 6, 10, 15 and 20 kV trunk overhead lines.

Voltage 6 – 20 kV
Conductor Al wires + steel wire
Cores 1 (covered)
Cross-section 35 – 95 mm²

SIPst-3 PRODUCT RANGE

The full list of manufactured cross-sections from the official TCG product range. Single-core covered conductor for 6–20 kV overhead lines.

Type / sizeCoresCross-section, mm²IEC equivalentOuter Ø, mmWeight, kg/km
SIPst-3 1×35135SAX12.2115
SIPst-3 1×50150SAX13.7162
SIPst-3 1×70170SAX15.4222
SIPst-3 1×95195SAX17295
Outer diameter and weight are given as typical values per GOST 31946-2012. The exact TCG factory parameters are provided in the product datasheet.

SIPst-3 wire description

SIPst-3 — self-supporting covered conductor for 6, 10, 15 and 20 kV medium-voltage overhead power lines. Structurally, it is a single-core wire with a conductor of aluminium wires reinforced with steel wire, in protective insulation of UV-stabilised cross-linked polyethylene.

Unlike conventional bare conductors, the insulation of SIPst-3 withstands contact with tree branches, which reduces the likelihood of emergency outages. It is used in areas with difficult terrain, in forested areas and in conditions of increased atmospheric pollution (atmosphere types II and III per GOST 15150).

Applications

6, 10, 15 and 20 kV trunk overhead lines
Line branches from medium-voltage overhead lines
Overhead lines in forested areas and areas with vegetation
Overhead lines in polluted atmospheres (atmosphere types II and III)
Replacement of bare A and AS conductors on existing overhead lines

Construction

1

Conductor

Stranded, compacted, made of aluminium wires, reinforced with steel wire.

2

Protective insulation

UV-stabilised cross-linked polyethylene (XLPE). Black, resistant to UV radiation and to contact with vegetation.

Cross-section of SIPst-3 (single-core wire with protective insulation)

Technical specifications

Rated voltage 6 / 10 / 15 / 20 kV
Conductor material Al wires reinforced with steel wire
Conductor class Stranded, compacted
Protective insulation UV-stabilised cross-linked polyethylene (XLPE)
Number of cores 1
Cross-sections 35 – 95 mm²
IEC equivalent SAX
Standard GOST 31946-2012

Detailed specifications (current-carrying capacity, resistance, weight, breaking strength) – to be added once the specifications file is uploaded

Operating conditions

Installation temperature not below -20°C
Operating temperature -60°C … +50°C
Max. conductor t° (continuous) +90°C
Max. conductor t° (short circuit) +250°C
Min. bending radius 10 × Ø
Application atmosphere types II, III (GOST 15150)
Service life at least 40 years
Warranty 5 years
Climatic category UHL

DOCUMENTS

REQUEST A PRICE

Specify the cross-section and quantity and we will prepare a proposal within 1 business day.