Cable finder
+998 (97) 748-80-00 +998 (71) 287-42-42 info@tcg.uz
KVVG Control
Control cables + armoured GOST 1508-78

KVVG

Control cable with copper conductors and PVC insulation

KVVG is a control cable with solid copper conductors, PVC compound insulation and sheath, and no protective covering. It is used for fixed connection to electrical instruments, apparatus and terminal assemblies in switchgear. Designation breakdown: K – control, V – PVC insulation, V – PVC sheath, G – unarmoured.

Voltage 660 V AC / 1000 V DC
Conductor Copper, solid
Cores 4 – 37
Cross-section 0.75 – 10 mm²

KVVG PRODUCT RANGE

Sizes with actual technical specifications from TCG factory data.

TypeCoresCross-section, mm²IEC equivalentOuter Ø, mmWeight, kg/km
KVVG 5×1.551.5NYY14.8251
KVVG 5×2.552.5NYY16.1316
KVVG 7×1.571.5NYY16.7309
KVVG 7×2.572.5NYY18.5403
KVVG 8×1.581.5NYY17.4344
KVVG 8×2.582.5NYY19442
KVVG 10×1.5101.5NYY18.4399
KVVG 10×2.5102.5NYY20.4527
KVVG 12×1.5121.5NYY19.3453
KVVG 12×2.5122.5NYY21.4602
KVVG 14×1.5141.5NYY20.4514
KVVG 14×2.5142.5NYY22.4676
KVVG 16×1.5161.5NYY21.2566
KVVG 16×2.5162.5NYY23.5760
KVVG 18×1.5181.5NYY21.9618
KVVG 18×2.5182.5NYY24.3832
KVVG 20×1.5201.5NYY22.8679
KVVG 20×2.5202.5NYY25.3916
KVVG 24×1.5241.5NYY24.1780
KVVG 24×2.5242.5NYY26.81059
KVVG 30×1.5301.5NYY26941
KVVG 30×2.5302.5NYY28.91284
The table lists 5-30-core versions with 1.5 and 2.5 mm² cross-sections – the most common in industrial process control systems. The full range under GOST 1508-78: 4-37 cores, cross-sections 0.75; 1; 1.5; 2.5; 4; 6; 10 mm². The exact product range is available on request.

KVVG cable description

KVVG is TCG's main control cable for control, signalling and automation systems in switchgear. Solid copper conductors (4-37 cores in increments per GOST) provide a reliable connection between terminal blocks and equipment contacts. Cross-sections of 0.75-10 mm² suit most control circuits and signal lines.

It is used in control cabinets, at distribution points, and for connecting sensors and actuators in automated control systems. It is not intended for installation in the ground without protection – for that, choose KVBbShv (armoured), or KVVGng(A)-LS for fire-hazard areas.

Applications

Control and signalling circuits of electrical installations
Switchgear up to 660 V
Automation (automated control systems) and supervisory control systems
Links between control cabinets and actuators
Fixed installation indoors and in cable structures

Construction

1

Conductors

Solid copper, round. From 4 to 37 cores with colour coding (or numbering for > 5 cores).

2

Insulation

PVC compound with core colour coding to GOST 1508-78.

3

Stranding

The insulated cores are stranded together to form the cable core.

4

Sheath

Black PVC compound. No protective covering.

KVVG cross-section – 5 solid copper conductors in PVC insulation

Technical specifications

Rated voltage AC 660 V, up to 100 Hz
Rated voltage DC up to 1000 V
Conductor material Copper
Conductor class 1 (solid)
Insulation PVC compound
Sheath PVC compound
Number of cores 4, 5, 7, 10, 14, 19, 27, 37
Cross-sections 0.75; 1; 1.5; 2.5; 4; 6; 10 mm²
IEC equivalent NYY (control)
Standard GOST 1508-78

Detailed specifications (conductor resistance, load current) – see the TCG datasheet

Operating conditions

Installation temperature not below -15°C
Operating temperature -50°C … +50°C
Max. conductor t° (continuous) +70°C
Max. conductor t° (short circuit) +160°C
Air humidity up to 98% at +35°C
Min. bending radius 7.5 × Ø (single-core), 10 × Ø (multi-core)
Service life at least 30 years
Warranty 5 years
Climatic category UHL

DOCUMENTS

REQUEST A PRICE

Specify the cross-section and quantity and we will prepare a proposal within 1 business day.