The laboratory is accredited to ISO/IEC 17025, the international standard setting out requirements for the competence of testing laboratories. It uses 85 test methods and carries out the full range of acceptance and periodic tests of cable products.
Electrical tests
- high-voltage insulation testing — for cables up to 35 kV;
- measurement of conductor resistance and insulation resistance;
- measurement of capacitance and dielectric loss tangent.
Dimensions and mechanical properties
- insulation and sheath thickness, outer diameter, ovality;
- breaking force and elongation at break;
- resistance to bending and impact;
- heat resistance and cold resistance.
Fire tests
- non-propagation of flame in single and bunched installation;
- smoke emission and corrosivity of combustion products — for ng-LS, FRLS and HF cables;
- fire resistance under mechanical impact to IEC 60331. The TCG laboratory is the first in Uzbekistan to perform such tests.
What the ng(A), LS, FR and HF indices mean is explained in the article “How to read a power cable type designation”.
Testing every batch
Every batch undergoes voltage testing, measurement of insulation and conductor resistance, and checks of the geometric parameters and mechanical properties of the insulation and sheath. For cables in special versions, fire resistance tests and smoke and gas emission tests are added.
Photos of the laboratory and the quality control department are in the photo report “Quality control and testing”. Product certificates are in the Certificates section.