VBShvng(A)-FRLS FR + LS + armour
Power cables 1 kV • fire-resistant GOST R 53316

VBSHVNG(A)-FRLS

Fire-resistant armoured power cable with a mica fire barrier

VBShvng(A)-FRLS is the armoured version of VVGng(A)-FRLS for installation in the ground and under mechanical stress. Double steel tape armour and an outer sheath of low-fire-hazard PVC are added to the fire-resistant construction with a mica fire barrier. Used in underground fire protection system lines, metro tunnels, underground car parks and industrial facilities.

Voltage 0.66/1 kV
Conductor Copper
Protection FR + ng(A) + LS + armour
Cross-section 2.5 – 240 mm²

VBShvng(A)-FRLS PRODUCT RANGE

Sizes with actual technical specifications: outer diameter (with armour), weight, continuous current-carrying capacity in air. Full range of cross-sections: 2.5 — 240 mm².

Type / sizeCoresCross-section, mm²IEC equivalentOuter Ø, mmWeight, kg/kmCurrent (in air), A
VBShvng(A)-FRLS 3×434—14.432134
VBShvng(A)-FRLS 3×636—15.639943
VBShvng(A)-FRLS 3×10310—17.454160
VBShvng(A)-FRLS 3×16316—19.674480
VBShvng(A)-FRLS 3×25325—23.21072101
VBShvng(A)-FRLS 3×35335—25.51391126
VBShvng(A)-FRLS 3×50350—271871153
VBShvng(A)-FRLS 3×70370—302480196
VBShvng(A)-FRLS 3×95395—35.23571238
VBShvng(A)-FRLS 3×1203120—384325276
VBShvng(A)-FRLS 3×1503150—41.95291319
VBShvng(A)-FRLS 3×1853185—46.36452364
VBShvng(A)-FRLS 3×2403240—51.68162430
VBShvng(A)-FRLS 4×444—15.638934
VBShvng(A)-FRLS 4×646—16.948943
VBShvng(A)-FRLS 4×10410—1967360
VBShvng(A)-FRLS 4×16416—21.493780
VBShvng(A)-FRLS 4×25425—25.41362101
VBShvng(A)-FRLS 4×35435—28.11778126
VBShvng(A)-FRLS 4×50450—29.72411153
VBShvng(A)-FRLS 4×70470—33.63243196
VBShvng(A)-FRLS 4×95495—38.84585238
VBShvng(A)-FRLS 4×1204120—42.45617276
VBShvng(A)-FRLS 4×1504150—46.86888319
Supplied on drums. Standard factory lengths – from 250 to 1000 m depending on the cross-section.

VBShvng(A)-FRLS cable description

VBShvng(A)-FRLS combines two important properties: fire resistance for fire safety systems and mechanical protection by armour for installation in the ground. The construction includes a fire barrier of mica-containing tapes over each conductor, armour of two galvanised steel tapes and an outer sheath of low-fire-hazard PVC compound.

Used where both fire resistance (90 minutes at 750°C) and protection against mechanical stress are required: routes between buildings, tunnels, underground car parks, industrial plants with a high fire load. Meets the requirements of Federal Law No. 123-FZ for critical loads.

Applications

Installation in the ground in fire protection systems
External emergency power supply and automatic fire protection networks
Metro tunnels, underground car parks
Facilities requiring both mechanical protection and fire safety
Industrial plants with a high fire load

Construction

1

Conductors

Stranded copper.

2

Fire barrier

Mica-containing tape over each conductor. Maintains circuit integrity under fire for ≥ 90 minutes.

3

Insulation

Low-fire-hazard PVC compound with colour coding.

4

Stranding and bedding under the armour

The insulated cores are stranded, with an extruded PVC bedding applied over them.

5

Armour

Two galvanised steel tapes applied helically with a gap of no more than 50% of the tape width.

6

Protective sheath

Low-fire-hazard PVC compound (LS), orange.

Cross-section of VBShvng(A)-FRLS – orange PVC sheath + steel armour + mica fire barrier around the conductors

Technical specifications

Rated voltage 0.66 / 1 kV
Conductor material Copper
Fire barrier Mica-containing tape
Insulation Low-fire-hazard PVC compound
Armour 2 galvanised steel tapes
Outer sheath Low-fire-hazard PVC compound (LS)
Fire resistance (FR) ≥ 90 min at 750°C
Flame propagation Does not propagate, category A
Number of cores 1, 2, 3, 4, 5
Cross-sections 2.5 – 240 mm²
Standards GOST 31996-2012, GOST 31565-2012, GOST R 53316

Full product range – see the TCG datasheet

Operating conditions

Installation temperature not below -15°C
Operating temperature -50°C … +50°C
Max. conductor t° (continuous) +70°C
Max. conductor t° (short circuit) +160°C
Fire resistance ≥ 750°C for 90 minutes
Air humidity up to 98% at +35°C
Min. bending radius 10 × Ø
Service life at least 30 years
Warranty 5 years