POWER CABLES 1 KV • HALOGEN-FREE + ARMOURED

Power cables with a halogen-free HF / LSZH sheath

Power cables for a rated voltage of 0.66/1 kV with a halogen-free (HF / LSZH) sheath. They contain no chlorine, bromine, fluorine, iodine or their compounds. When burning they emit no corrosive gases or acrid smoke — critical for metro systems, tunnels, data centres, server rooms, nuclear power plants and offshore facilities, where halogen-containing materials are prohibited or undesirable. The category includes the basic HF (Cu and Al) and the fire-resistant FRHF with a mica fire barrier.

Sheath Halogen-free (HF / LSZH)
Fire safety Does not propagate flame; FR version
Voltage 0.66/1 kV (up to 3 kV)
Application Metro, data centres, facilities with electronics
PvPGng(A)-HF HF / LSZH

PvPGng(A)-HF

GOST 31996-2012
Halogen-free power cable with copper conductors and XLPE insulation
Voltage 0.66/1 kV
Conductor Copper
Sheath HF – halogen-free
Cross-section 1.5 – 1000 mm²
Product range:
3×1.5 3×2.5 3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150
APvPGng(A)-HF Al + HF

APvPGng(A)-HF

GOST 31996-2012
Halogen-free power cable with aluminium conductors and XLPE insulation
Voltage 0.66/1 kV
Conductor Aluminium
Sheath HF – halogen-free
Cross-section 2.5 – 1000 mm²
Product range:
3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150 4×185
PPGng(A)-FRHF FR + HF

PPGng(A)-FRHF

GOST R 53316
Fire-resistant halogen-free power cable with a mica fire barrier
Voltage up to 3 kV
Fire resistance FR + ng(A) + HF
Fire barrier Mica-based tape
Cross-section 1.5 – 1000 mm²
Product range:
3×1.5 3×2.5 3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150

COMPARISON OF HALOGEN-FREE TYPES

ParameterPvPGng(A)-HFAPvPGng(A)-HFPPGng(A)-FRHF
ApplicationPremises with electronics and peopleTrunk lines in halogen-free areasFire safety systems
ConductorCopperAluminiumCopper
Fire barrierNoneNoneMica-containing tape
InsulationCross-linked polyethylene (XLPE)Cross-linked polyethylene (XLPE)Halogen-free polymer compound
SheathHalogen-free (HF)Halogen-free (HF)Halogen-free (HF)
Halogen content0%0%0%
Flame propagationDoes not propagate (ng, cat. A)Does not propagate (ng, cat. A)Does not propagate (ng, cat. A)
Fire resistance (FR)——≥ 90 min at 750°C
Smoke when burningMinimalMinimalMinimal
Gas corrosivityEmits no corrosive gasesSameSame
Number of cores1–51–51–5
Cross-sections, mm²1.5–10002.5–10001.5–1000
Voltage0.66/1 kV0.66/1 kVup to 3 kV
StandardGOST 31996-2012, GOST 31565-2012GOST 31996-2012, GOST 31565-2012GOST 31996-2012, GOST 31565-2012, GOST R 53316